EXT_Service_SaveService
Function to save the service
Input parameters:
- inServiceExercise – Exercise of the technical service
- inServiceSeries - Series of the technical service
- inServiceNumber - Number of the technical service
- inKeepTemporaryData - If MSS must keep the information on the temporary tables (must be used, for example, to print the service)
- inSignatureFilename1- Name of the file with customer signature, it must be saved in the MSS Temp folder (PVAR(MSSFrameworkV51, MultiCompany_Folder) + "\Temp")
- inSignatureFilename2 - Name of the file with technic signature, it must be saved in the MSS Temp folder (PVAR(MSSFrameworkV51, MultiCompany_Folder) + "\Temp")
Output parameters:
- outResultCode – 0 – OK / -3 – Error or user canceled
- outServiceExercise – Exercise of the technical service created (only when inNewOrEdit = )
- outServiceSeries - Series of the technical service
- outServiceNumber - Number of the technical service