2421 - New / Start intervention
2421 - New / Start intervention
| Event | Extension action set | Description |
|---|---|---|
| Before | EXT_2421_1_Before | Will be executed before MSS starts a new intervention or press + button to create a new one; |
| Replace | EXT_2421_2_Replace | Will replace MSS start or create a new intervention code, can be used also to create validations before MSS run the default code on the start of a new intervention using the output parameter outRunMSSCode; |
| After | EXT_2421_3_After | Will be executed after MSS runs the Start intervention code or after close the new intervention screen; |
Before
Input Parameters
- inServiceExercise – Exercise of the service (SITEXR);
- inServiceSeries – Serie of the service (SITSER);
- inServiceNumber – Number of the service (SITNDC);
- inEquipmentLine – Line number of equipment (SITLEQ);
Replace
Input Parameters
- inServiceExercise – Exercise of the service (SITEXR);
- inServiceSeries – Serie of the service (SITSER);
- inServiceNumber – Number of the service (SITNDC);
- inEquipmentLine – Line number of equipment (SITLEQ);
Output Parameters
- outRunMSSCode – when replacing MSS module must return 0(zero), if working as validations can return 1 so MSS starts or creates the intervention, 0 to ignore MSS code or -1 to abort the operation;
- outNewInterventionLine – Number of the new intervention when replacing MSS code;
After
Input Parameters
- inServiceExercise – Exercise of the service (SITEXR);
- inServiceSeries – Serie of the service (SITSER);
- inServiceNumber – Number of the service (SITNDC);
- inInterventionLine – Line number of intervention (SITLIN);
- inEquipmentLine – Line number of equipment (SITLEQ);