Nordic ID NUR Read Tag
Kalipso - Form - Actions - Actions Description - Group RFID - Nordic ID NUR Read Tag
Reads a Nordic ID NUR Tag data.
Action available for the following operating systems:
Parameters
Address
Memory Bank <unquoted string> - Defines the memory bank to this read action. The possible values are:
EPC
User
Reserved
TID
Dynamic
Start Address <numeric> - he address where the read action begins. Normally it must be a multiple of 2.
Nbr. of Bytes <numeric> - The number of bytes to read. Normally it must be a multiple of 2.
Target <unquoted string> - The control or variable to save the data readed in this action.
Details
Coded <unquoted string> - Indicates if the readed data is coded or not. The possible values are: Yes, No or dynamic. Use Yes if the established connection is in String Data Mode.
Access Password <string> - The password defined if the user uses Class1 Generation2 tags.
Filter
Apply Filter <string> - Specifies if a filter is to be applyed.
Memory Bank <string> - Selectes the memory bank for the filter. Specifying "-1 - EPC ID Content" indicates that the filter should be done on the EPCID inside the EPC memory bank. It is equivalent to making the filter on the EPC memory bank with "Bit Position" parameter = 32.
Mask Value <string> - Hexadecimal mask value to be used for the filter.
Bit Position <string> - Starting bit position for the filter.
Bit Lenght <string> - Number of bits to use from the "Mask Value".
Send Ext. Carrier Command - This is a special option to send a specific command to the reader and have the antena carrier with the command be active during the read operation.
Extended Carrier Command - The extended command to be sent in ASCII bytes.
Nbr of Bits - The number of bits in the command to be used.
Last updated